MBH-60

MBH-60

CT Scanner

MBH-60
DESCRIPTION:

64-slice CT system integrating the most advanced imaging technologies. Intelligent large-bore 64-slice CT scanner designed for high-performance clinical applications.

FEATURES

IMPROVED X-RAY EFFICIENCY

SAFE, EFFICIENT, LOW DOSE

LOW-DOSE TECHNOLOGY

COMPREHENSIVE APPLICATIONS

  • Interventional Department: Biopsy, ablation, and treatment procedures.

  • Radiotherapy Department: CT simulation.

  • Oncology Department: Tumor imaging, evaluation, follow-up, and treatment assessment.

  • Orthopedics Department: 3D and VR imaging for fracture visualization.

  • Medical Examination Center: Low-dose screening and automated diagnosis.

  • Neurology Department: Stroke evaluation and vascular morphological analysis.

  • Respiratory Department: Lung nodule analysis, pneumonia detection, and pulmonary function assessment.

  • Radiology Department: Full-body scanning.

Oncology
MBH_300-PLUS-8-RESPIRATORIO
Respiratory

TECHNICAL
SPECIFICATIONS

IMAGE RECONSTRUCTION

  • Reconstruction Field of View (FOV): 50–500 mm; 50–650 mm (extended)

  • Reconstruction Matrix: 512 × 512, 768 × 768, 1024 × 1024

  • Reconstruction Speed: ≥ 40 fps (images per second)

  • Display Matrix: 1024 × 1024


IMAGE OPTIMIZATION ALGORITHMS

  • Metal Artifact Reduction: Standard

  • Beam Hardening Artifact Reduction: Standard

  • Partial Volume Artifact Reduction: Standard

  • Ring Artifact Reduction: Standard

  • Helical Scan Artifact Reduction: Standard

  • Motion Artifact Reduction: Standard


IMAGE QUALITY

  • Spatial Resolution: ≥ 21 lp/cm @ 0% MTF; XY plane: ≥ 15 lp/cm @ 0% MTF; Z plane

  • Low-Contrast Resolution: 2 mm @ 0.3% @ 25 mGy

  • Image Noise: < 0.35% (central dose of 40 mGy)

CT Number Scale (HU):

  • Standard: –1024 HU to +3072 HU

  • Extended: –32768 HU to +32767 HU

MBH_300-PLUS-4
Respiratory
Neurology

COMPUTER SYSTEM:

DIMENSIONS AND WEIGHT

Patient Table

Length: 580 mm.
Width: 2400 mm.
Height: 950 mm.
Weight: 350 kg.

Gantry

Length: 1970 mm.
Width: 940 mm.
Height: 1850 mm.
Weight: 1200 kg.

Console

Length: 400 mm.
Width: 630 mm.
Height: 630 mm.
Weight: 50 kg.
MBH_HealthMedic

Interested in our product?
Get in touch with us!
Send us your details and request a quote now.

sales@mbh-hc.com

Be part of this great family that is always committed to delivering the very best for you.
Our clients are always our top priority.

OPERATING ENVIRONMENT:

Scan Room Dimensions

  • Minimum Area: 18 m² (5000 mm × 3600 mm)

  • Recommended Room Size: 30 m² (6000 mm × 5000 mm)

  • Recommended Height: 2650–3050 mm (if the 3D Vision Camera is selected)

Temperature:

  • Scan Room: 20–26 °C

  • Control Room: 18–28 °C

Humidity:

  • Scan Room: 30%–70%, non-condensing

  • Control Room: 20%–80%, non-condensing

POWER SUPPLY REQUIREMENTS

Power Capacity: 50 kVA.
Power Supply Option: Three-phase 380 VAC, voltage variation tolerance < ±10%.
Frequency: 50 Hz or 60 Hz, tolerance < ±1 Hz

INTELLIGENT ENERGY SAVING

Our scanners are designed for energy efficiency and feature an optimized standby mode, which reduces the operation of high-voltage control and data acquisition devices. Only essential components remain active during standby. This design does not affect normal startup performance, while significantly reducing annual power consumption. When the system operates 10 hours per day, 6 days per week, annual energy consumption is reduced by 2,815 kWh, which is 62.5% lower than the previous design.

2815

k W- h